Battery tester

Battery Analyzer Maintainer Charger Dischager for 3.2 to 16V all batteries

    • Model: BM6018
  • Input: 100~240Vac
  • Output: 2.0~18.0Vdc, 0.4~4.0A
  • Functions: Analyze, Charge, Maintain, Discharge. 
    • Battery type: Lead-acid, Lithium-ion, LiFePO4, NiMh/NiCd
  • Output Protections: OVP, OCP, OTP, Shorted, Reversed
    • Safety Approval: CE FCC

INQUIRY NOW
  • 12V 24V Battery Analyzer
  • Battery charger analyzer
  • DESCRIPTION
  • TECHNICALS
  • DATASHEET DOWNLOAD
This device is an intelligent instrument that integrates the four functions of battery testing(analyzing)chargingdischarging and maintenance. It is designed with a portable plastic shell, and with color TFT displayer and silicon touch keys.

It is a powerful assistant for electronic engineers. It can be used to excute performance testing, capacity testing, characteristic curve measurement, and activation and maintenance of long-term storage batteries for various commonly used rechargeable batteries.

It is widely used for performance testing and routine maintenance of most rechargeable batteries in many portable electronics/electrical devices (such as smart phone, tablet PC, drone, e-bike, e-scooter, power tool, car …).

Can analyze, charge, discharge and maintenance batteries below,

Lead acid:      4V 6V 8V 10V 12V 14V

Lithium-ion:    3.7V 7.4V 11.1V 14.8V

LiFePO4:        3.2V 6.4V 9.6V 12.8V 16V

NiMh/NiCd:    3.6V 4.8V 6V 7.2V 8.4V 9.6V 10.8V 12V 13.2V 14.4V

Can Analyze 24 lead acid battery as well.


4 main functions:

  • Charge: can set constant current & constant voltage for charging process.
  • Discharge: can set constant current value & cut-off voltage for discharging.
  • Test/analyze: can measure battery voltage, internal resistance, SOC, SOH, true effective capacity Ah value and charge/discharge curves.
  • Maintenance: for the battery that has been left standing or in standby for more than 6 months, do a auto maintenance process to keep or recover battery good active capacity and health life.
  • AC input power: 100~240V 50HZ

  • Suitable battery type: Lead-Acid(AGM, VRLA, SLA, Gel), Li-Ion, LiFePO4, NiMH, NiCd

  • Charging method: PreCharge -- C.Cbulk charge -- special charge CV or CC -- end charge

  • Suitable battery voltage*: 2.0V ~ 16.0V (For 24V battery, can only provide test function, no charge)

  • Charge/discharge voltage range: 2.0V ~ 18.0V

  • Charge current range: 0.4A ~ 4.0A (60W Max.)

  • Discharge current range: 0.2A~2.0A (8W Max.)

  • Temperature compensation: Auto compensation charge voltage according to environment temperature

  • Voltage test precision: +/- 1.0%

  • Current test precision: +/- 2.5%

  • Capacity test precision: +/- 2.5%

  • Abnormal protection: Shorted, reversed, OVP, OCP, OLP, OTP.

  • Size and weight: 160*88*35mm, 330g

  • Safety standard: CE, EN62368, EN61000