We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
6V-7.2V 400mA NiMh Charger for 5S-6S 400-3200mAh battery packs
Wall mout NiMH or NiCad charger useful for 6V and 7.2V
packs, 6 volt pack charger, 7.2 volt pack charger, 7.2v nimh charger, 7.2 volt charger
This
is a sophisticated smart battery charger which will work with 5-cell and 6-cell
nickel cadmium and nickel metal hydride battery packs. These 6V and 7.2V have
a universal AC input and so can be used in any country in the
world.
5S-6S 0.4A SMART NIMH BATTERY CHARGER |
||||
NO |
ITEM |
UNIT |
SPECIFICATION |
REMARK |
INPUT |
||||
01 |
RATING INPUT |
V ac |
100~240Vac 50/60Hz |
|
02 |
INPUT RANGE |
V ac |
90~264Vac |
|
03 |
RATING INPUT CURRENT |
A |
0.1Arms |
INPUT:120V OUTPUT:Full load |
04 |
MAX. INPUT POWER |
W |
6 |
|
OUTPUT |
||||
05 |
RATING OUTPUT VOLTAGE |
V dc |
9.6V |
|
06 |
OUTPUT VOLTAGE RANGE |
V dc |
6VDC ~ 12VDC |
12V is open-circuit voltage |
07 |
SUIT WITH BATTERY |
Ah |
6.0~7.2V 500~2800mAh NIMN/NICD |
|
08 |
CHARGE CURRENT |
A |
0.42 ±0.07A |
|
09 |
TRICKLE CURRENT |
A |
<0.05 |
|
11 |
INNER TIMMER (typical) |
hour |
8 |
From 1~10 hours, defined by user |
12 |
MAX. OUTPUT POWER |
W |
4W |
|
13 |
HOLD-ON TIME |
ms |
NC |
Input: 120Vac Output: Full load |
14 |
RIPPLE CURRENT |
mA |
30 |
Input: 120Vac Output: Full load |
15 |
MAIN CHARGE END CONDITION |
|
-DV > 5mV /CELL (typical) or VMAX>=1.6V/cell(typical) or Timer out. |
For NiCd battery, Vmax is 1.8V/cell This value can be defined by user. |
16 |
LED INDICATION |
|
RED: MAIN CHARGE GREEN: FINISHED |
|
17 |
Output shorted Protection Output reverse Protection |
- |
YES No |
|
18 |
EFFICIENCY |
% |
60% |
At max. load |
ENVIRONMENT |
||||
19 |
OPERATE TEMP. |
°C |
-10 ~ +40 |
Full load & natural convection. |
20 |
OPERATE HUMIDITY |
%RH |
< +90 |
Relative humidity, non-condensing. |
21 |
STORAGE TEMP. |
°C |
-40 ~ +70 |
|
22 |
STORAGE HUMIDITY |
%RH |
0 ~ +95 |
Relative humidity, non-condensing. |
23 |
COOLING |
- |
Natural convection |
|
24 |
TEMP. FACT |
% |
-- |
|
25 |
VIBRATION |
|
5MM/50HZ/600S |
Non-operating condition. |
26 |
IMPACT |
|
1 meter drop test >= 3 times |
Non-operating condition. |
MECHANICAL |
||||
27 |
WEIGHT |
g |
120 |
|
28 |
SIZE |
mm |
81X51X28 |
Casing only |
29 |
Input/Output Cord and Connecters. |
- |
Defined by user |
|
SAFETY |
||||
30 |
TEMP. RISE |
°C |
< 40 on casing |
At any line and Max. Load |
31 |
SAFETY STANDARD |
- |
EN60950 UL1950 |
|
32 |
EMC |
- |
EN55022 B |
|
33 |
MTBF |
hrs |
30000 |
|
34 |
ESD |
kV |
8.0 |
|
35 |
HI-POT |
V |
i/p to o/p: 3000 (1 min.) |