We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
6V-12V 0.9A&1.8A dual output Charger for 5S-10S 1.8-14Ah NiMh NiCd battery charger
6S-10S Multi-point Smart NiMh Battery Charger
|
||||
NO |
ITEM
|
UNIT
|
SPECIFICATION
|
REMARK
|
INPUT
|
||||
01
|
RATING INPUT
|
V ac
|
100~240Vac 50/60Hz
|
|
02
|
INPUT RANGE
|
V ac
|
90~264Vac
|
|
03
|
RATING INPUT CURRENT
|
A
|
0.4Arms
|
INPUT:220V OUTPUT:Full load
|
04
|
MAX. INPUT POWER
|
W
|
40
|
|
OUTPUT
|
||||
05
|
RATING OUTPUT VOLTAGE
|
V dc
|
16V
|
|
06
|
OUTPUT VOLTAGE RANGE
|
V dc
|
7VDC ~ 20VDC
|
|
07
|
SUIT WITH BATTERY
|
Ah
|
7.2 ~12V 1.2~14Ah NIMN/NICD
|
MCU auto detective.
|
08
|
CHARGE CURRENT
|
A
|
1.8 ± 0.2 and 0.9+-0.1A
|
Manual switch select
|
09
|
TRICKLE CURRENT
|
A
|
<0.25A or 0.13A
|
|
11
|
INNER TIMMER
|
hour
|
8hours (default)
|
1~10 hours defined when order.
|
12
|
MAX. OUTPUT POWER
|
W
|
30W
|
|
13
|
HOLD-ON TIME
|
ms
|
NC
|
Input: 220Vac Output: Full load
|
14
|
RIPPLE CURRENT
|
mA
|
90
|
Input: 220Vac Output: Full load
|
15
|
MAIN CHARGE END CONDITION
|
|
-DV > 5mV /cell (TYP)
or Vmax>=1.6V/cell
or Timer out.
|
For NiCd, Vmax is 1.8V/cell
|
16
|
LED INDICATION
|
|
RED: MAIN CHARGE
GREEN: FINISHED
|
|
17
|
Output Short-circuit Protection
Output Reverse Protection
|
-
|
yes
yes
|
|
18
|
EFFICIENCY
|
%
|
80%
|
At max. load
|
ENVIRONMENT |
||||
19
|
OPERATE TEMP.
|
°C
|
-10 ~ +40
|
Full load & natural convection.
|
20
|
OPERATE HUMIDITY
|
%RH
|
< +90
|
Relative humidity, non-condensing.
|
21
|
STORAGE TEMP.
|
°C
|
-40 ~ +70
|
|
22
|
STORAGE HUMIDITY
|
%RH
|
0 ~ +95
|
Relative humidity, non-condensing.
|
23
|
COOLING
|
-
|
Natural convection
|
|
24
|
TEMP. FACT
|
%
|
--
|
|
25
|
VIBRATION
|
|
5MM/50HZ/600S
|
Non-operating condition.
|
26
|
IMPACT
|
|
1 meter drop test >= 3 times
|
Non-operating condition.
|
MECHANICAL
|
||||
27
|
WEIGHT
|
g
|
250
|
|
28
|
SIZE
|
mm
|
117X61X37
|
Casing only
|
29
|
AC&DC CONNECTER
|
-
|
Defined when order
|
|
SAFETY
|
||||
30
|
TEMP. RISE
|
°C
|
< 40 on casing
|
At any line and Max. Load
|
31
|
SAFETY STANDARD
|
-
|
EN60335 UL1310
|
|
32
|
EMC
|
-
|
EN55014 B
|
|
33
|
MTBF
|
hrs
|
30000
|
|
34
|
ESD
|
kV
|
8.0
|
|
35
|
HI-POT
|
V
|
i/p to o/p: 3000 (1 min.)
|
For final unit, cut-off current =10mA
|