We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
3.6V-4.8V 600mA Charger for 3-4 cells 1200-4800mAh NiMh NiCd Battery packs
External NiMH or NiCad charger useful for 3.6V and 4.8V packs, 3.6 volt pack charger, 4.8 volt pack charger, 4.8v nimh charger, 4.8 volt charger
This is a sophisticated smart battery charger which will work with 3-cell and 4-cell nickel cadmium and nickel metal hydride battery packs. These 3.6V and 4.8V have a universal AC input and so can be used in any country in the world.
3.6V 4.8V 600mA Smart NiMh Battery Charger
|
||||
NO |
ITEM
|
UNIT
|
SPECIFICATION
|
REMARK
|
INPUT
|
||||
01
|
RATING INPUT
|
V ac
|
100~240Vac 50/60Hz
|
|
02
|
INPUT RANGE
|
V ac
|
90~264Vac
|
|
03
|
RATING INPUT CURRENT
|
A
|
0.1Arms
|
INPUT:230V OUTPUT:Full load
|
04
|
MAX. INPUT POWER
|
W
|
8
|
|
OUTPUT
|
||||
05
|
RATING OUTPUT VOLTAGE
|
V dc
|
6V
|
|
06
|
OUTPUT VOLTAGE RANGE
|
V dc
|
3VDC ~ 6VDC
|
6V is open circuit voltage
|
07
|
SUIT WITH BATTERY
|
Ah
|
3.6~4.8V 0.7~5Ah NIMN/NICD
|
|
08
|
CHARGE CURRENT
|
A
|
0.7 A ( +0.1A)
|
|
09
|
TRICKLE CURRENT
|
A
|
<0.07
|
|
11
|
INNER TIMMER(default)
|
hour
|
8
|
Defined by user
|
12
|
MAX. OUTPUT POWER
|
W
|
5W
|
|
13
|
HOLD-ON TIME
|
ms
|
NC
|
Input: 230Vac Output: Full load
|
14
|
RIPPLE CURRENT
|
mA
|
20
|
Input: 230Vac Output: Full load
|
15
|
MAIN CHARGE END CONDITION
|
|
-DV > 5mV /CELL(TYP)
or VMAX>=15V
or Timer out.
|
|
16
|
LED INDICATION
|
|
RED: MAIN CHARGE
GREEN: FINISHED
|
|
17
|
Output Short-circuit Protection
Output Reverse Protection
|
-
|
YES
NO
|
|
18
|
EFFICIENCY
|
%
|
75%
|
At max. load
|
ENVIRONMENT |
||||
19
|
OPERATE TEMP.
|
°C
|
-10 ~ +40
|
Full load & natural convection.
|
20
|
OPERATE HUMIDITY
|
%RH
|
< +90
|
Relative humidity, non-condensing.
|
21
|
STORAGE TEMP.
|
°C
|
-40 ~ +70
|
|
22
|
STORAGE HUMIDITY
|
%RH
|
0 ~ +95
|
Relative humidity, non-condensing.
|
23
|
COOLING
|
-
|
Natural convection
|
|
24
|
TEMP. FACT
|
%
|
--
|
|
25
|
VIBRATION
|
|
5MM/50HZ/600S
|
Non-operating condition.
|
26
|
IMPACT
|
|
1 meter drop test >= 3 times
|
Non-operating condition.
|
MECHANICAL
|
||||
27
|
WEIGHT
|
g
|
100
|
|
28
|
SIZE
|
mm
|
65X61X26
|
Casing only
|
29
|
DC Cable & CONNECTER
|
-
|
Defined by user
|
|
SAFETY
|
||||
30
|
TEMP. RISE
|
°C
|
< 40 on casing
|
At any line and Max. Load
|
31
|
SAFETY STANDARD
|
-
|
EN60335 or EN60950
|
|
32
|
EMC
|
-
|
EN55013 or EN55022B
|
|
33
|
MTBF
|
hrs
|
30000
|
|
34
|
ESD
|
kV
|
8.0
|
|
35
|
HI-POT
|
V
|
i/p to o/p: 3000 (1 min.)
|
For final unit, cut-off current =10mA
|