We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
We supply Lead Acid, Lithium-ion, LiFePO4, NiMh NiCd battery chargers, battery tester, battery desulphator and power supply for every device and application.
24V 2.8A NiMh NiCd Battery charger with battery fuel gauge displaying and NTC function
|
24V 20S 3A Smart NiMH Battery Pack Charger
|
|||||||||
NO |
ITEM
|
UNIT
|
SPECIFICATION
|
REMARK
|
|||||
|
INPUT
|
|||||||||
|
01
|
RATING INPUT
|
V ac
|
100~240Vac 50/60Hz
|
|
|||||
|
02
|
INPUT RANG
E
|
V ac
|
90~264Vac
|
|
|||||
|
03
|
RATING INPUT CURRENT
|
A
|
0.8Arms
|
INPUT:220V OUTPUT:Full load
|
|||||
|
04
|
MAX. INPUT POWER
|
W
|
95
|
|
|||||
|
OUTPUT
|
|||||||||
|
05
|
RATING OUTPUT VOLTAGE
|
V dc
|
32V
|
|
|||||
|
06
|
OUTPUT VOLTAGE RANGE
|
V dc
|
20VDC ~ 36VDC
|
|
|||||
|
07
|
SUIT WITH BATTERY
|
Ah
|
24V 3~20AH NI-MH
|
|
|||||
|
08
|
CHARGE CURRENT
|
A
|
1.8A ±0.2A or 2.8A
|
|
|||||
|
09
|
TRICKLE CURRENT
|
A
|
<0.1A
|
|
|||||
|
11
|
INNER TIMMER
|
hour
|
8hour
|
T.B.D. 1~10 hours.
|
|||||
|
12
|
MAX. OUTPUT POWER
|
W
|
65W
|
|
|||||
|
13
|
HOLD-ON TIME
|
ms
|
NC
|
Input: 220Vac Output: Full load
|
|||||
|
14
|
RIPPLE CURRENT
|
mA
|
<150
|
Input: 220Vac Output: Full load
|
|||||
|
15
|
MAIN CHARGE END CONDITION
|
|
dT/dt>=0.5 °C/min(TYP)
or -ΔV >= 5mV /CELL(TYP)
or Vmax>=1.6V/CELL
or Tmax>=50+-2°C
or Time out
|
|
|||||
|
16
|
LED INDICATION
|
|
RED: Main charge
GREEN: Finish or idle
GREEN LED FLASH: Errors
|
Error: Output short-circuit. Battery
reversed, NTC errors……
|
|||||
|
17
|
Output Short-circuit Protection
Output Reverse Protection
|
-
|
yes
yes
|
|
|||||
|
18
|
EFFICIENCY
|
%
|
80%
|
At max. load
|
|||||
ENVIRONMENT |
|||||||||
|
19
|
OPERATE TEMP.
|
°C
|
-10 ~ +40
|
Full load & natural convection.
|
|||||
|
20
|
OPERATE HUMIDITY
|
%RH
|
< +90
|
Relative humidity, non-condensing.
|
|||||
|
21
|
STORAGE TEMP.
|
°C
|
-40 ~ +70
|
|
|||||
|
22
|
STORAGE HUMIDITY
|
%RH
|
0 ~ +95
|
Relative humidity, non-condensing.
|
|||||
|
23
|
COOLING
|
-
|
Natural convection
|
|
|||||
|
24
|
TEMP. FACT
|
%
|
Less than 5%
|
|
|||||
|
25
|
VIBRATION
|
|
5MM/50HZ/600S
|
Non-operating condition.
|
|||||
|
26
|
IMPACT
|
|
1 meter drop test >= 3 times
|
Non-operating condition.
|
|||||
|
MECHANICAL
|
|||||||||
|
27
|
WEIGHT
|
g
|
650
|
|
|||||
|
28
|
SIZE
|
mm
|
170*71*51
|
Casing only
|
|||||
|
29
|
CONNECTER
|
-
|
DC PLUG: 3-PIN TPYE +, - , NTC
AC PLUG: Defined when order
|
NTC type: temperature sensor resister
10K&B=3950
|
|||||
|
SAFETY
|
|||||||||
|
30
|
TEMP. RISE
|
°C
|
< 40 on casing
|
At any line and Max. Load
|
|||||
|
31
|
SAFETY STANDARD
|
-
|
EN60335 UL1310
|
|
|||||
|
32
|
EMC
|
-
|
EN55014 B
|
|
|||||
|
33
|
MTBF
|
hrs
|
30000
|
|
|||||
|
34
|
ESD
|
kV
|
8.0
|
|
|||||
|
35
|
HI-POT
|
V
|
i/p to o/p: 3000 (1 min.)
|
For final unit, cut-off current =10mA
|
|||||
| File Name | Size | File Type | Date | Download |