ITEM | UNIT | SPECIFICATION | REMARK | |||||
INPUT | ||||||||
01 | Rating Input Voltage | V ac | 100~240Vac 50-60Hz | |||||
02 | Input voltage range | V ac | 90~264Vac | |||||
03 | Rating Input Current | A | 0.3Arms | 220Vac | ||||
04 | Max.input power | W | 52.5W | |||||
OUTPUT | ||||||||
05 | Rating output voltage | V dc | 12.6V | |||||
06 | Output voltage range | V dc | 0VDC~12.6VDC | |||||
07 | Suit with Battery type | 11.1V Li-ion battery charger and capacity>3000mAh | ||||||
08 | Charging current(stage1) | A | 3.0±0.3 | |||||
09 | Charging voltage(stage2) | V | 12.4-12.65V | |||||
10 | Cut-off current(stage1→2) | A | 0.2-0.4A | |||||
11 | Typical charging time | hour | Fast charge 2hours Slow charge 5hours | |||||
12 | Max.output power | W | 42.0W | |||||
13 | Hold-on time | ms | NC | Input:220Vac Output:Full load | ||||
14 | Ripple current | mA | 150 | Input:220Vac Output:Full load | ||||
15 | Charge finish condition | I<0.40A | ||||||
16 | LED color | Green on:charging;Green flash:fully charged;Red on:power on; Yellow on:Battery temperature in high or low;Yellow on:Incorrect battery type or Battery NG | ||||||
17 | Output protect | - | OCP&OVP | |||||
18 | Efficiency | % | 80%(Typical) | At max.load | ||||
Environment | ||||||||
19 | Operate temperature | ℃ | 0~+40 | Full load&natural convection | ||||
20 | Operate humidity | %RH | 20~90 | Relative humidity,non-condensing. | ||||
21 | Storage temperature | ℃ | -40~+70 | |||||
22 | Storage humidity | %RH | 10~95 | Relative humidity,non-condensing. | ||||
23 | Cooling | - | Natural convection | |||||
24 | Temperature factor | % | -- | |||||
25 | Vibration resistance | 5MM/50HZ/600S | Non-operating condition. | |||||
26 | Impact resistance | 1 meter drop test>=3 times | Non-operating condition. | |||||
Mechanical | ||||||||
27 | Weight | g | ||||||
28 | Size | mm | Casing only | |||||
29 | Connectors | - | ||||||
Safety | ||||||||
30 | Max.temperature rise | ℃ | <40 on casing | At any line and Max.Load | ||||
31 | Safety standards | - | ||||||
32 | EMC standard | - | ||||||
33 | MTBF | hrs | 40000 | |||||
34 | Limited power source | VA | - | |||||
35 | ESD | Kv | 8.0 | |||||
36 | Hi-Pot Insulation | v | Input to Output:3000Vac(1 min.) | For final nuit,cut-off current=10mA |